<Frequency setting mode selection>
[Parameter setting]
Title

[Programmed value]
:
:
:
:
:
:
:
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
Frequency setting mode selection 1
Frequencies are set by rotating the setting dial on the inverter and an extension
panel option. Like the position of notches in a volume knob, the frequency setting
Setting dial 1
value at the position of the notch is saved.
 Refer to section 3.2.2
A frequency command is set by means of external analog signals.
Terminal VIA
(VIA terminal: 0 –10Vdc)
 Refer to section 3.2.2 and 7.3
A frequency command is set by means of external analog signals.
Terminal VIB
(VIB terminal: 0 - +10Vdc or -10 - +10Vdc)
 Refer to section 3.2.2 and 7.3
Frequencies are set by rotating the setting dial on the inverter and an extension
panel option. Press the center of the setting dial to save the frequency setting
Setting dial 2
value.
 Refer to section 3.2.2
RS485
Frequencies are set by RS485 communication from an external device.
 Refer to section 6.38
communication
UP/DOWN from
Frequencies are set by up/down commands from a terminal.
external logic input
 Refer to section 6.10.4
CANopen
Frequencies are set by CANopen communication from an external device.
 Refer to "CANopen communication Instruction Manual E6581911".
communication
Adjustment range
0: Setting dial 1 (including extension panel
option) (save even if power is off)
1: Terminal VIA
2: Terminal VIB
3: Setting dial 2 (including extension panel
option) (press in center to save)
4: RS485 communication
5: UP/DOWN from external logic input
6: CANopen communication
7: Communication option
8: Terminal VIC
9, 10: -
11: Pulse train input
12, 13: -
14: sro
F-13
E6581611
Default setting
0
6