6.32 Analog input terminal function selection

f214 : VIB input point 1 rate
f215 : VIB input point 2 rate
f663 : Analog input terminal function selection (VIB)
 Function
Parameter is normally set from operation panel. However some parameters can be continuously set from
external analog input by using this function. VIB terminal is used.
[Parameter setting]
Title
f214  VIB input point 1 rate
f215  VIB input point 2 rate
f663 
● Analog input terminal function assigns VIB terminal. The range of analog input voltage is 0% to +100%.
From -100% to 0% cannot be used.
● The parameter that is selected by f663 can be adjusted range as following table.
Setting of f663
0: Frequency
command
1: Acceleration/
deceleration time
2: Upper limit
frequency
5: Torque boost
value
6: Stall prevention
level
7: Motor electronic-
thermal protection
level
11: Base frequency
voltage
Note: Adjustments are made by the inverter itself, so no changes are made to parameter settings
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
Analog input terminal function
selection (VIB)
Object parameter
-
acc , dec , f500 ,
f501 , f510 , f511
ul
vb , f172
f185 , f601
thr , f173
vlv , f171
Adjustment range
-250-+250 (%)
-250-+250 (%)
0: Frequency command
1: Acceleration/deceleration time
2: Upper limit frequency
3, 4: -
5: Torque boost value
6: Stall prevention level
7: Motor electronic-thermal protection level
8 to 10: -
11: Base frequency voltage
VIB : 0% input
-
Parameter setting value x
f214
Parameter setting value x
f214
Parameter setting value x
f214
Parameter setting value x
f214
Parameter setting value x
f214
Parameter setting value x
f214
F-119
E6581611
Default setting
0
100
0
VIB : 100% input
-
Parameter setting value x
f215
Parameter setting value x
f215
Parameter setting value x
f215
Parameter setting value x
f215
Parameter setting value x
f215
Parameter setting value x
f215
6