Utility mode
8
Check that the distance from the starting print position of the test
pattern to the edge of the paper (d) is 3 mm (±0.5 mm).
–
If the distance is 2.4 mm or less, touch [+] to increase the
adjustment (between 0.2 mm and 3.0 mm).
–
If the distance is 3.6 mm or more, touch [-] to reduce the adjustment
(between -0.2 mm and -3.0 mm).
–
If the distance is between 2.5 mm and 3.5 mm, continue with step
10.
–
Each time [+] or [-] is touched, the value is increased or decreased
by one increment.
9
Press the [Start] key.
The adjusted test pattern is printed.
10
Adjust the distance from the starting print position of the test pattern to
the edge of the paper.
–
Check that the distance has been adjusted to between 2.5 mm and
3.5 mm.
–
If more adjustment is necessary, repeat steps 8 and 9.
–
To adjust the print position for a different paper tray, return to step
6.
11
Touch [OK].
–
To cancel the setting and select the default, press the [Reset] key.
The print position is adjusted.
C451
d: 3.0 mm ± 0.5 mm
11
d
11-69