Utility Screen Outlines
Setting Item/Description
04 Reset Setting
01 Auto Reset Setting
Set the reset interval starting from the completion of a
copying job until the machine returns to the initial con-
dition, without selecting any key on the touch panel or
the control panel.
Off/ 60 seconds/ 120 seconds/ 180 seconds/ 240 sec-
onds/ 300 seconds/ 360 seconds/ 420 seconds/ 480
seconds/ 540 seconds
02 Mode Reset Setting
Select whether or not to initialize the setting currently
specified when the machine takes it that the user has
changed, or original document is loaded into the ADF.
And select the settings to be initialized each time a sin-
gle job has been completed.
Change user/ ADF original direction/ Reset button
function/ Mode memory auto call/ Finisher Mode by
Full-auto/ Initial by Key Counter Insert/ Status Hold
When Auto Reset/ Next Job Staple Setting/ Original
Set/Bind Direction
05 Default Screen Setting
Select the initial screen to be displayed when the power
switch is turned on.
Machine/ Job List/ Copy
06 Preset Zoom Setting
Modify predefined fixed ratios, and preset frequently used
magnification ratios.
Fixed/Six type
Preset Zoom/Three type
07 Power Save Setting
Set the interval time of Auto Low Power and Auto Shut Off
modes.
Auto Low Power: OFF/ 5 min./ 10 min./ 15 min./ 30 min./ 60
min./ 90 min./ 120 min./ 240 min.: 5 min.
Auto Shut Off: OFF/ 1 min./ 30 min./ 60 min./ 90 min./ 120
min./ 240 min.: OFF/30 min.
08 Time and Date Setting
Set the present time, summer time, and time zone.
Setting Time/ Summer Time/ Time zone
09 Buzzer Setting
01 Buzzer Volume Regulation
Set the buzzer sound (the touch key sound) as touch-
ing the screen.
On/ Off, Big/ Small
02 Buzzer for Job Stop Set
Select the duration of the buzzer sound when the ma-
chine stops due to no paper and mishandled paper.
Off/ 3 seconds/ 5 seconds/ 10 seconds
bizhub PRO C6501
Default
60 seconds
Change user: Yes
ADF original direction: Not
reset
Reset button function: Full
auto
Mode memory auto call: Off
Finisher Mode by Full-auto:
None collate
Initial by Key Counter Insert:
Off
Status Hold When Auto Re-
set: Not keep
Next Job Staple Setting: Do
Not Release
Original Set/Bind Direction:
Release
Machine
Fixed/Six type
Preset Zoom/Three type
Auto Low Power: 5 min.
Auto Shut Off: 30 min.
Setting Time/ Summer Time
(Off)/ Time zone
On
Off
4-13