Accessing A Rack-Installed Server; Extending The Server From The Rack - HP AB464-9003F Service Manual

Hpe integrity rx6600 server user
Table of Contents

Advertisement

I/O voltage regulator module
Trusted Platform Module
PCI/PCI-X card divider
Core I/O board
Core I/O board battery
SAS core I/O card
LAN core I/O card
Doorbell board
Display board
SAS backplane board
Interconnect board
Midplane board

Accessing a Rack-Installed Server

The following procedure explains how to gain access to a server that is installed in an approved
rack. For rack installation instructions, review the document titled Installation Guide, Mid-Weight
Slide Kit, 5065-7291. You can access this document at:
http://www.hpe.com/support/rx6600-manuals
WARNING!
adequate ballast properly placed, and so on) are employed prior to extending the server from
the rack.

Extending the Server from the Rack

NOTE:
Ensure that there is enough area (approximately 1.5 meters [4.5 ft.]) to fully extend the
server from the front of the rack.
To extend the server from the rack, follow these steps:
1.
Remove the T25 screws with the orange tags that fasten the front of the server to the rack
(Figure
53).
2.
Remove the orange screws from the rear of the rack located on the left and right slide rails.
3.
Flip out the two pull handles located on both ends of the front bezel
4.
Slowly pull the server forward by the handles until it is fully extended.
NOTE:
cover is completely accessible.
176 Removing and Replacing Server Components
Ensure that all antitip features are employed (front and rear antitip feet installed;
The server is fully extended when the rail clips are locked in place and the top
(Figure
53).