5.
Open ORCA. See
If using a headless console, press Esc+8.
Otherwise, press F8.
6.
Configure the logical boot drive, and exit from ORCA.
Depending on the OS, additional device drivers and management agents must be installed. See
the User Guide for the specific Smart Array Controller at:
http://www.hpe.com/info/integrity-iocards-docs under the specific Smart Array Controller
product for installation procedures.
The latest firmware, drivers, utilities, software, and documentation for Integrity servers are available
on the Hewlett Packard Enterprise website at http://www.hpe.com/support/itaniumservers.

Connecting External Storage

IMPORTANT:
To connect external storage, follow these steps:
1.
Power off the server.
2.
Connect an external SAS cable to the external port of the controller.
NOTE:
the controller preferentially discovers devices attached to port 1E. However, drives on the
shared internal port are unavailable until you disconnect the external storage device.
3.
Tighten the lock screws on the cable connector.
4.
Attach the other end of the cable to the SAS input connector of the external storage enclosure.
IMPORTANT:
either all SAS or all SATA. (Parallel SCSI drives cannot be used with this controller.)
5.
Tighten the lock screws on the cable connector.
6.
Power on the enclosure.
7.
Power on the server.

SAS Cable Part Numbers

If you require additional cables, order them by the option kit number listed in
Table 88 SAS Cable Part Numbers
Cable Length
1.0 m (3.3 ft.)
2.0 m (6.6 ft.)
4.0 m (13 ft.)
6.0 m (20 ft.)

SAUPDATE Utility

Use saupdate from the EFI Shell to update the firmware image on the Smart Array P600.
Command line options are described below. Follow one of these two procedures to run saupdate:.
If you are using saupdate from the Offline Diagnostic CD:
1.
Download the firmware and copy it to the EFI partition.
2.
The CD containing saupdate.efi must be in the drive before booting the system to allow
device mapping.
306 Core I/O Card Utilities
"Configuring the Array" (page
Not all OSs, or Smart Array cards support external drives.
You do not have to disconnect any internal drives on shared internal port 1I because
Drives that are to be used in the same array must be of the same type,
Option Kit Number
389664-B21
389668-B21
389671-B21
389674-B21
312).
Cable Assembly Number
361317-001
361317-002
361317-004
361317-006
Table
88.