HP AB464-9003F Service Manual page 154

Hpe integrity rx6600 server user
Table of Contents

Advertisement

05-Diagnostic Panel 06-Front Panel 00-Motherboard
Log Entry 4: Dec 2005 00:00:09
Alert Level 5: Critical
Keyword: Type-02 257100 2453760
Missing CRU device - Mem Extender
Logged by: Baseboard Management Controller,
Sensor: Entity Presence
0x2000000009020050 FF01807115250300
If you do not see all of the above CRU IDs, concentrate on the missing CRU IDs. You should
eventually end up with the following Alert (IPMI) event for this action as read from the SEL:
If you do not get the above Alert Level 5 (IPMI) event, but get another sort of high level alert,
try replacing the I/O backplane board. Examine the pins on the midplane board, and if
necessary, replace the midplane board.
5.
The next step would be to add the memory extender (with at least one rank of DIMMs).
Remember to remove the AC power cord(s) before making this configuration change.
Here is the output of the iLO 2 MP> DF command you should expect at this point (this example
has two ranks of DIMMs installed).
CRU IDs:
--------
0152-DIMM0D 0001-Mem Extender 0002-Power Converter
0003-Power Supply 0 0004-Power Supply 1 0005-Diagnostic Panel
0006-Front Panel 0128-DIMM0A 0136-DIMM0B
0144-DIMM0C 0160-DIMM1A 0168-DIMM1
0176-DIMM1C 0184-DIMM1D 0000-Motherboard
If you do not see all of the above CRU IDs, concentrate on the missing CRU IDs. You should
eventually end up with the following Alert (IPMI) event for this action as read from the SEL:
If you do show the Alert level 5 "Missing CRU device - CPU 0 PIROM", continue to the next
step.
Log Entry 3: Dec 2005 21:50:43
Alert Level 5: Critical
Keyword: Type-02 257100 2453760
Missing FRU device - CPU 0 PIROM
Logged by: Baseboard Management Controller,
Sensor: Entity Presence
0x2041CB3DB3020040 FF20807115250300
154 Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents