HP AB464-9003F Service Manual page 98

Hpe integrity rx6600 server user
Table of Contents

Advertisement

Pred Fail
Size(MB)
View Array Screen
The View Array screen enables you to view the current array configuration. To access the View
Array screen, press Enter on the View Existing Array field from the Select New Array Type
screen.
You can perform the following actions on the View Array screen:
To view the next array, press N.
To create a new array, press C.
Array
Identifier
Type
Scan Order
Size (MB)
Status
Bay
Device Identifier
RAID Disk
Hot Spr
98
Installing the System
Wrg Type
Device is not compatible for use as part of an IM
array.
Too Small
Disk is too small to mirror existing data.
Max Dsks
Maximum # of disks allowed for this type of Array
reached and/or Maximum # of total IM disks on a
controller reached.
No SMART
Disk doesn't support SMART, cannot be used in
an RAID array.
Wrg Intfc
Device interface (SAS) differs from existing IM
disks.
Indicates whether device SMART is predicting device failure (Yes,
No).
Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576). If the device is part of a two-disk array, this field
reflects the size of the array, not the size of the individual disk. If the
device is part of a three or more disk array, this field is the size that
the disk makes up within the array. When creating a striped array,
the usable size of the array is determined by the number of drives
times the size of the smallest drive in the array. In arrays consisting
of different sized drives, excess space on larger drives are unusable.
Displays the number of this array.
Displays the identifier of this array.
Displays the RAID type.
Displays the scan order of the array.
Displays the size of the array.
Displays the status of the array.
Displays the bay in which devices are located.
Displays the device identifier.
Specifies the devices (disks) that make up an IM array. If RAID Disk
is Yes, the device is part of an IM array, if No, the device is not part
of an IM array. This field is grayed out under the following conditions:
The device does not meet the minimum requirements for use in
an IM array.
The device is not large enough to mirror existing data on the
primary drive.
This disk has been selected as the hot spare for the IM array.
Specifies whether a device is the hot spare for an IM array. If hot
spare is Yes, the device is used as a hot spare for the IM array, if No,
the device is not used as a hot spare for the IM array. Only one hot

Advertisement

Table of Contents
loading

Table of Contents