HP AB464-9003F Service Manual page 225

Hpe integrity rx6600 server user
Table of Contents

Advertisement

4.
If rack installed, slide the server completely out from the rack. See
from the Rack" (page
5.
Remove the top cover. See
6.
Disconnect the internal USB cable from the connector on the core I/O board.
7.
Disconnect the SAS cables attached to the SAS core I/O card in PCI slot 1.
CAUTION:
When disconnecting the SAS cables, note the labeling on the cables. Both
cables and sockets are clearly marked with the correct channel. When reconnecting these
cables, match each cable with the appropriate socket on the SAS core I/O card. If the cables
are mismatched, the server will not reboot.
8.
Slide the server completely back into the rack.
9.
Open the cable management arm wide enough to slide the I/O board out the rear of the
rack.
10. Disconnect all external cabling attached to ports at the rear of the chassis.
11. Press in on the retention levers to unlock the I/O board assembly extraction handles
(Figure
77).
12. Pull the I/O board assembly extraction handles outward to unplug the I/O board assembly
from the socket on the midplane board.
13. Slide the I/O board assembly all the way out the rear of the chassis
NOTE:
The I/O board assembly is large. Use care when lifting it out of the server chassis.
176).
"Removing the Top Cover" (page
178).
Removing and Replacing the I/O Board Assembly 225
"Extending the Server
(Figure
77).

Advertisement

Table of Contents
loading

Table of Contents