HP ProLiant DL980 G7 Maintenance And Service Manual page 81

Hide thumbs Also See for ProLiant DL980 G7:
Table of Contents

Advertisement

TIP:
The estimated time for this update is approximately one hour.
a.
Download the Smart Component to a directory on the hard drive and change to that
directory.
Download the FMP firmware for the Windows operating system
pub/softlib2/software1/sc-windows-fw/p2062200202/v68009).
Download the FMP firmware for the Linux operating system
softlib2/software1/sc-linux-fw/p1438027470/v68004).
b.
From that drive and directory, execute the downloaded file. Linux users can execute "sh
CPxxxxxx.scexe" where CPxxxxxx.scexe represents the filename of the component. Click
"Install" when prompted.
c.
If the first update pass fails, retry flashing the FMP.
d.
If the second update pass fails, browse to the iLO web information Diagnostics tab and
use the Reset button to reset iLO.
e.
Retry flashing the FMP.
f.
Upon successful update, the following dialog box will appear.
CAUTION:
components in this procedure have been updated.
12.
Shutdown the OS.
13.
Unplug all power cables from the server, and wait at least 30 seconds.
CAUTION:
After flashing the System Programmable Logic Devices, the power must cycle
for the changes to take effect. All power cables must be unplugged for at least 30 seconds to
allow the components to lose their residual charge. Pressing the power button is not sufficient.
14.
If installing new processors
15.
Connect the power cables to the server.
16.
Power up the server (dc on).
17.
Verify post by watching post codes through iLO IRC (bottom banner). This step is optional,
but recommended.
Do not power off or power down the server until the firmware for all
("Processor" (page
(ftp://ftp.hp.com/pub/
44)), install them now.
Flashing firmware using Smart Components
(ftp://ftp.hp.com/
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents