4.
Close the processor socket retaining bracket and the processor locking lever.
CAUTION:
processor locking lever. The lever should close without resistance. Forcing the lever closed
can damage the processor and socket, requiring system board replacement.
5.
Clean the old thermal grease from the heatsink with the alcohol swab. Allow the alcohol to
evaporate before continuing.
6.
Apply all the grease to the top of the processor in the following pattern to ensure even
distribution.
48
Removal and replacement procedures
Be sure to close the processor socket retaining bracket before closing the