Server Specifications - HP ProLiant DL980 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL980 G7:
Table of Contents

Advertisement

Server Specifications

Specification
Dimension
Height
Depth
Width
Weight (maximum)
Weight (one hard drive, power supply and processor
installed)
Input requirement
Rated line voltage
Rates input current
Rated input frequency
Input power (maximum)
BTUs rating (maximum)
Power supply output (per power supply)
Rated steady-state power
Rated input power
Maximum peak power
1
To ensure the server has sufficient power during normal operation, a server configured with eight populated CPU sockets
or a detected high power GPU requires high line (200 - 240 V) ac server configuration. As a precaution, if these
configurations are detected on a low line (100 - 127 V) ac configured server the server will halt at Power-On Self-Test
with a "Low line (100- 1 20 VAC) power delivery is not sufficient for this configuration. High line (200-240 VAC) delivery
is required to operate the system in its current configuration" message and only boot to RBSU.
At POST, the server automatically detects whether the power supplies are connected to high-line
power or low-line power. If the server is configured with eight populated CPU sockets or a detected
high power GPU, the system will halt if it detects that the server is plugged into low-line power.
This occurs by design because systems configured eight processors, and/ or high power graphics
cards, with a large amount of memory, hard drives, or other options might require more power
than can be provided by low-line power. POST halts this low-line configuration as a precaution
against the server having insufficient power during operation.
If a you wish to operate a server in this configuration when utilizing low-line power, the power
supply solution should be verified as sufficient using the HP Power Advisor
go/hppoweradvisor). If the power solution is not deemed sufficient, the server may not have
1
Value
35.36 cm (13.92 in)
87.63 cm (34.5 in)
48.26 cm (19.0 in)
93 kg (205 lb)
75 kg (165 lb)
100-240 VAC
9.3A @ 100 VAC
9.5A @ 108- 1 20 VAC
6.6A @ 200-240 VAC
50–60 Hz +/- 3hz
4600 W
14,444 BTU/hr (worst case configuration and utilization)
800 W @ 100 VAC
900 W @ 1 10- 1 20 VAC
1200 W @ 200-240 VAC
950W @ 100 VAC
1075W @ 108–120 VAC
1375W @ 200-240 VAC
960 W @ 100 VAC
1080 W @ 1 10- 1 20 VAC
1440 W @ 200-240 VAC
(http://www.hp.com/