Systems Insight Display Assembly - HP ProLiant DL980 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL980 G7:
Table of Contents

Advertisement

6.
Remove all components from the failed SPI board.
To replace the component, reverse the removal procedure.

Systems Insight Display assembly

CAUTION:
they can be pinched or crimped.
To remove the component:
1.
Power off the server
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Using a T- 1 0 Torx screwdriver, release the two locking latches on the top of the SID bezel.
5.
Pull the bezel up and away from the server.
6.
Disconnect the cable from the rear of the Systems Insight Display assembly.
7.
Remove the retaining screw.
8.
Remove the Systems Insight Display assembly.
When routing cables, always be sure that the cables are not in a position where
("Power off the server" (page
22)).
Systems Insight Display assembly
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents