Sas Backplane; Xnc Module - HP ProLiant DL980 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL980 G7:
Table of Contents

Advertisement

NOTE:
On an HP ProLiant DL980 G7 server with a 128 logical CPU configuration, if an HP
NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter is located in any Low Profile
IO slot, the network connection may drop or the NIC may stop responding. This can occur while
running Windows Server 2008 R2 and HP Network Configuration Utility for Windows Server
2008 R2 Version 10.10 or Version 10.20. To prevent network connections from dropping, upgrade
to HP Network Configuration Utility for Windows Server 2008 R2 Version 10.30 (or later).

SAS backplane

To remove the component:
1.
Power down the server.
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Remove all hard drives
5.
Disconnect all cables from the SAS backplane.
6.
Release the locking latch.
7.
Remove the SAS backplane.
To replace the component, reverse the removal procedure.

XNC module

1.
Power off the server
2.
Release the latches on the release lever.
("SAS/SATA hard drive" (page
("Power off the server" (page
22)).