Position of the knife holder

.47.03
Requirement
Adjustment gauge 1 should
1. Be parallel to the stationary cutting edge and
2. Be positioned in the centre of the cutout in the needle plate insert.
Fig. 13 - 46
Remove the knife and fit adjustment gauge 1.
Press down the knife bracket by hand and set knife holder 2 (screws 3) in accordance
with the requirements.
Remove adjustment gauge 1 and insert the knife.
Carry out a manual cutting test, see Chapter 13.47.06 Manual cutting test.
Adjustment
3
1
2
83-025