Upper take-up lever position
.17
Requirement
The take-up lever should position 1.8 - 2.0 mm before its t.d.c. and one of the screws 1
should be accessible.
Fig. 13 - 13
Remove the needle and switch on the machine.
Select parameter "609".
Press Enter, the motor turns to the reference point.
Loosen screw 1 and, by turning the balance wheel 2, bring the take-up lever into position
according to the requirement.
Tighten screws 1.
Switch off the machine.
(reference position)
2
56-057a