Omron SYSDRIVE 3G3JV User Manual page 159

Compact simplified inverters
Hide thumbs Also See for SYSDRIVE 3G3JV:
Table of Contents

Advertisement

Communications
Communications
Board
Port 1
Port 2
Port A
Port B
DM 6555
DM 6550
DM 6556
DM 6551
Note Use the settings marked with an asterisk in the above table.
7-34
Bit
00 to 03
Port settings
0 Hex: Standard settings (default setting)
1 Hex*: Settings in DM 6556/6551
04 to 11
00: Default setting
12 to 15
Serial communications mode
0 Hex: Host Link (default setting); 1 Hex: No-protocol;
2 Hex: 1:1 Data Link slave; 3 Hex: 1:1 Data Link
master; 4 Hex: NT Link in 1:1 mode; 5 Hex: NT LInk in
1:N mode; 6 Hex*: Protocol macro
00 to 07
Baud rate (unit: bps)
00 Hex: 1,200 (default setting); 01 Hex: 2,400;
02 Hex: 4,800: 03 Hex*: 9,600; 04 Hex: 19,200
08 to 15
Frame format:
Setting
00 Hex
01 Hex
02 Hex
03 Hex
04 Hex
05 Hex
06 Hex
07 Hex
08 Hex*
09 Hex
10 Hex
11 Hex
Meaning
Start bit
Data
Stop
length
1
7
1
1
7
1
1
7
1
1
7
2
1
7
2
1
7
2
1
8
1
1
8
1
1
8
1
1
8
2
1
8
2
1
8
2
Chapter 7
Setting
6001
0803
Parity
bits
Even
(default
setting)
Odd
None
Even
Odd
None
Even
Odd
None
Even
Odd
None

Hide quick links: