Preparing for Operation and Monitoring
H Copying the Memory Contents of the Digital Operator to the Inverter
(CPy)
• The parameter settings saved in the memory of the Digital Operator can be written to the Inverter by
setting the Parameter Copy and Verify Function (n76) to "Cpy."
• When reading from the Digital Operator has been completed, turn OFF the Inverter power supply and
remove the Digital Operator.
• Install the Digital Operator on the Inverter to which the parameters are to be written and turn ON the
power supply.
• In the Parameter Write-prohibit Selection/Parameter Initialization (n01) is not set to 1 for that Inverter,
use the same procedure as described above to set it to 1.
Note Parameters can be copied only between Inverters with the same power supply specifications.
D Procedure for Writing the Memory Contents of the Digital Operator
Key sequence
Indicators
(After
completion)
or
Note 1. A setting range check and consistency check will be performed for the parameters after the
memory contents of the Digital Operator have been written to the Inverter. If there is one or
more parameters with an error, all parameters will be returned to their previous settings and
none of them will be changed.
If there is a setting range error, the number of the parameter that caused the error will flash.
If there is a consistency error, oPj (j as a number) will flash.
Note 2. The saved hold output frequency and the following parameters cannot be copied.
n76: Parameter Copy and Verify Function
n77: Parameter Read Prohibit Selection
n78: Error Log
n79: Software Number
3-14
Display
example
Power ON
Press the Mode Key until the PRGM indicator lights.
Use the Increment or Decrement Key to display n76.
Press the Enter Key. "rdy" will be displayed.
Press the Increment Key to display "Cpy."
Press the Enter Key. The parameters in the memory of
the Digital Operation will be written to the Inverter.
During this time, the display will flash.
When writing has been completed, "End" will be
displayed.
Press the Mode Key or the Enter Key to return to the
parameter number display.