Specifications
H Standard Specifications
Input signal
Measurement method
Input impedance
Sampling period
Display refresh period
Max. displayed digits
Display
Polarity display
Zero display
Scaling function
Hold function
Comparative output
hysteresis setting
Other functions
Output
Delay in comparative outputs 750 ms max.
Degree of protection
Memory protection
H Connection Example
3-phase
power supply
DC voltage/current (0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, ±5 V, ±10 V)
Double integral method
Current input: 45 Ω max., Voltage input: 1 MΩ min.
250 ms
Sampling period (sampling times multiplied by number of measurements for
averaging if average processing is selected.)
5 digits (–19999 to 99999)
7-segment digital display
"–" is displayed automatically with a negative input signal.
Leading zeros are not displayed.
Programmable with front-panel key inputs. The range of the display
conforms to the maximum displayed digits. The decimal point position can
be set as desired.
Max hold (maximum value), Min hold (minimum value)
Programmable with front-panel key inputs (0001 to 9999).
Forced-zero (with front-panel key)
Zero-limit
Scaling teach function
Display color change (green (red), green, red (green), red)
OUT type change (upper limit, lower limit, upper/lower limit)
Average processing (simple average: OFF or 2, 4, or 8 times)
Relays: 2 SPST-NO
Front panel: NEMA4X for indoor use (equivalent to IP66)
Rear case: IEC standard IP20
Terminals: IEC standard IP00 + finger protection (VDE0106/100)
Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)
Inside the Inverter
Circuit breaker
R
R
S
S
T
T
SYSDRIVE
Analog
monitor
U
IM
V
W
Analog output
+
E4
–10 to 10 VDC
E5
GND
E
Chapter 9
A1
A2
K3MA-J
9-11