To install a BCM50 unit on top of another unit

1
Insert the power supply retention clip into the BCM50 unit.
2
Place the BCM50 unit on top of the other unit. Make sure the feet of the unit are in the slots on
the top of the unit and in front of the slots (see
3
Slide the unit back until it clicks in place on the slots.
4
Continue with the next step,
Figure 31 BCM50 unit slots and feet

To install the power supply on the rackmount shelf

1
Place the power supply behind the BCM50 units on the back of the rackmount shelf.
Make sure the power supply is on its side with the label facing the back of the shelf.
2
Use two cable ties to secure the power supply to the rackmount shelf.
3
Repeat steps 1 and 2 for each power supply you are mounting.

To install the patch panel (optional)

1
Determine the location in the rack where you want to install the patch panel.
2
Position the patch panel in the rack.
3
Align the holes in the patch panel with the holes in the equipment rack rails.
4
Fasten the patch panel to the rack using the four rack screws (supplied with the patch panel).
5
Proceed to
"To install the power supply on the rackmount
Slots
"To connect the cables to the patch panel (optional)" on page
Chapter 7 Installing the main unit
Figure
31).
Feet
BCM50 Installation and Maintenance Guide
83
shelf".
111.