Gas Insert Aeration System; Minimum Fireplace Opening - Regency Energy E33-NG10 Owners & Installation Manual

Hide thumbs Also See for Energy E33-NG10:
Table of Contents

Advertisement

GAS INSERT
AERATION SYSTEM
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue flame or close for a yellower
flame. The burner aeration is factory set but may
need adjusting due to either the local gas supply
or altitude.
Minimum Air Shutter Opening:
5/16"
Natural Gas
7/16"
Propane
CAUTION: Carbon will be produced if air
shutter is closed too much.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
Note: Aeration Adjustment should only be
performed by an authorized Regency
Installer at the time of installation.

MINIMUM FIREPLACE OPENING

The minimum fireplace opening for the Regency gas fireplace insert is shown in the following diagram
and the table:
Max Lentil
Bar Depth
A
Low Profile
Faceplate with
8"
Spacer
Low Profile
Faceplate
9 1/4"
without Spacer
Vignette
9 1/2"
faceplate with
Spacer
Vignette
Faceplate
12"
Without Spacer
installation
A
B
C
Width
Height
Depth
(Rear)
B
C
D
24 3/16"
16 3/4"
25"
25 1/2"
18"
25"
24"
16 3/4"
25"
25 1/2"
19 1/8"
25"
E33-10 FPI Direct Vent Gas Insert
|
13
Width
Front Depth
(Front)
Width
Prior to Taper
E
F
G
N/A
32 1/4"
N/A
N/A
35 1/4"
N/A
N/A
32 1/2"
N/A
34 5/8"
35 3/4"