LOG SET INSTALLATION

WARNING:
Dangerous operating conditions may occur if these
logs are not positioned in their correct certifi ed loca-
tions. Read the following instructions carefully and
refer to the attached diagrams.
Gas Log Kit #340-930 contains the following:
03-17
Bottom Log
03-18
Center Top Log
03-19
Front Log
03-20
Left Log
03-21
Right Log
03-22
Left top Log
03-23
Rear Log
03-24
Right Top Log
946-669
Platinum Embers
03-18
03-22
03-20
03-17
The "03" reference numbers (i.e. 03-23) are molded
into the rear of each log.
1) Remove and carefully unwrap the logs from the
box. Please handle with care and do not force
them into position to avoid chipping.
2) Remove the safety screen and glass door if al-
ready installed.
918-416a
18 |
E33-10 FPI Direct Vent Gas Insert
DIRECT VENT FIREPLACE
LOG INSTALLATION
(supplied in packaged manual)
03-23
03-24
03-19
03-21
3) Remove the grate by removing the two Phillips
screws. Slide the grate outwards to remove it from
the unit (refer to Diagram 1).
4) Angle log 03-17 and slide it between the top and
bottom burner tube under the "T" section until it
touches the left grate support bracket (refer to
Diagram 2).
5) Re-install the grate.
6) Line up the pin holes (located at the bottom of log
03-23) to the pins of the rear log support and posi-
tion them into place. (refer to Diagram 3)
03-23
Page 1 of 3
Diagram 1
03-17
Diagram 2
Locating Pins
Diagram 3