Step 7: Check Power Supply Circuit Breakers and Fuses

This step is only needed if you experience problems with the system.
WARNING! Whenever the cabinet top cover is removed, use extreme caution. Do not
touch any internal power supply components because hazardous voltages
may be exposed. Whenever adding/removing power supply components or
checking circuit breakers and fuses, unplug the power supply AC plug from
the AC source outlet.
Step 7A: Check the -24 Volt Circuit Breakers
The APSU112 provides two -24v circuit breakers as shown in
between –24 volts and ground exists the circuit breaker will trip. Usually the front panel DC green
LED indicator will turn off but not always. Also if AC power is recycled the DC LED indicator
may turn back on – even if the –24 volt circuit breaker is tripped.
Circuit Breaker Location and Slot Assignments (see
The circuit breaker V1, located directly below the FG screw, protects the first and second
cabinet slots.
The circuit breaker V2, located next to the BASE jumper connector, protects the third and
fourth cabinet slots.
Reset Circuit Breaker
1. A defective PCB or an external short on the MDF may cause the circuit breaker to trip.
2. If you suspect that a –24 volt circuit breaker has tripped, try to reset it by:
• Turn the power supply DC power switch off and unplug the power supply AC power cord
from the AC outlet – the inside of the power supply has exposed voltages.
• Gently press in each circuit breaker and listen for or try to feel it click. If the breaker was
tripped, you will hear or feel it click back to the set position.
• If the circuit breaker resets, pull the PCBs and check for MDF shorts associated with the
slots assigned to the tripped circuit breaker. Remove any defective PCBs and MDF shorts.
• Restore power and verify the system is working normally.
3. Replace the power supply if the circuit breaker continues to trip and a defective PCB or short
cannot be found. See
2-17.
Step 7B: Check the AC Power Fuses
The APSU112 provides two AC power fuse as shown in
exists the fuse may blow. The front panel AC green LED indicator will turn off.
If you suspect that a AC fuse has blown you may check it by:
1. Turn the power supply DC power switch off and unplug the power supply AC power cord from
the AC outlet – the inside of the power supply has exposed voltages.
2. Remove each fuse and check that it is less than 0.3 ohms. Replace the fuse if it is defective. The
fuse size is T6.3AH 250V.
3. If you replace the fuse and it continues to blow, pull the PCBs and check for cabinet shorts.
Remove any defective PCBs and cabinet shorts.
Strata CTX I&M
10/02
"Step 7D: Remove and Replace the Power Supply (if required)" on page
Strata CTX100 Installation
Installing the CTX100 Cabinet
Figure
2-14. If a low resistance
Figure
2-14)
Figure
2-14. If low resistance to ground
2-15