Network/Csu/Rdtu Span Test - Toshiba STRATA CTX100 Installation And Maintenance Manual

Digital business telephone systems
Hide thumbs Also See for STRATA CTX100:
Table of Contents

Advertisement

Network/CSU/RDTU Span Test

This test checks all equipment that is checked with the test in the above paragraph, but this test
also checks that the RDTU Mitel LSI chip is functioning. Guidelines for this test are described in
Figures
6-8~6-10.
Note
Loop back tests with CSU and Network equipment can also be performed when connecting
the RDTU PCB directly to a customer premise (PBX, Key Hybrid, Channel bank) T1
circuit.
The RDTU Self Test is an active test of the RDTU circuit.
The Network/CSU Test checks all cables, the Network and CSU equipment (RDTU is not active).
The Remote Loop Back (RLB) Test is an Active test of RDTU (LSI MM8976B), CSU, Network
equipment and all cables.
Refer to
Figure 6-4
information on CSU Local/Network Loopback Tests.
RDTU
RDTU TX Open
MITEL Chip
P4
MM8976B
0
Top LED
0
0
0
0
0
Bottom LED
0
Figure 6-10
Network/CSU/RDTU Span Test
Strata CTX I&M
10/02
and the CSU manufacturer's Installation and Maintenance manual for
RDTU Amphenol Pin Nos.
P1/P26 Transmit
P2/P27 Receive
LEDS ON RDTU PCB
Busy
ON Steady
FALM
ON
FMALM
OFF
YALM
OFF
BALM
OFF
T1
T2
Primary SYNC
ON or OFF, Steady
Secondary SYNC
ON or OFF, Steady
NDTU Cable
Network
Interface
CSU
Unit (NIU)
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
T3
T4
T5
T6
Loop Back Testing
Network
2581
Continue to Cycle when
P4 is in ON Position
T = About 1/2 Second
1673
T1
6-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx670

Table of Contents