3 POWER SUPPLY REMOVAL
AND
REPLACEMENT
3.00 The power supply comes factory-installed
in
the Key Service Unit (Figure 4-5); if necessary,
it
can be removed
and replaced.
3.10 Power Supply Removal (Figure 4-5)
1)
2)
3)
4)
5)
6)
7)
Make sure that the power supply switch is OFF
and that the AC power
cable is not plugged
into an outlet.
Confirm
that green AC LED is
not lit.
Loosen
the screws
on the front cover of the
Key Service Unit, and remove
the cover.
Unplug
HPFB cable from BATT connector
of
powersupplyanddisconnecttheHPFBground
wire (Figure 4-5).
Unplug the AC cable from the CNI connector
on the power supply (Figure 4-5).
Remove
the FG screw,
and disconnect
the
green third wire ground
ring terminal
(Figure
4-5).
Unplug the DC cable from the CN3 connector
on the power supply (Figure
4-5).
Remove
the top two, and bottom
left corner
screws that attach the power supply to the Key
Service Unit. Remove
power supply.
3.20 Power Supply Replacement (Figure 4-5)
1)
Set the power supply in its proper place in the
Key Service
Unit (Figure 4-5).
2)
Secure
the power
supply to the Key Service
Unit with the top two, and bottom
left corner
screws.
4.10 DK8 Power Failure Emergency Transfer
Installation.
Install
the
dedicated
emergency
standard
telephone
as follows
(see Figure 4-6):
1) Connect
a standard
telephone
to the PFl
connector
in the Base Unit.
4.20 DK8 Power Failure Emergency Transfer
Test.
3)
Install the green third wire ground
ring terminal
with the FG screw.
1) Turn the system
power switch off.
4)
Plug the AC cable into the CNl
connector
on
2) Lift the emergency
standard
telephone
hand-
the power supply (Figure 4-5).
set, and verify that there is CO dial tone.
5)
6)
7)
Plug the DC cable into the CN3 connector
on
the power supply (Figure 4-5).
Plug the AC power
cable into an outlet
and
turn ON the power supply switch.
Test QPSU8
power
supply
according
to the
DK8
Hardware
Fault
Isolation
procedure,
Section
100-816-500,
Paragraph
6.
8)
Plug HPFB
cable
into BATT
connector
of
power supply and reconnect
the HPFB ground
wire (Figure 4-5).
9)
Reinstall
the cover on the key service unit.
INSTALLATION-OK8 KSU & PCB
SECTION 100-816-204
MARCH 1993
4 DK8 POWER FAILURE
EMERGENCY
TRANSFER
OPTION
4.00
A dedicated
standard
telephone
can be con-
nected
to the Power
Failure
Transfer
Interface
(PFl)
on the Key Service
Unit to provide
power
failure
backup.
During
normal
operation,
this
telephone
cannot
be used-it
does not count as a
station;
so it does
not reduce
the system's
10
maximum
station capacity.
But if there is a power
failure,
the telephone
will automatically
be con-
nected
to CO line 1. When power is restored,
the
system
will automatically
resume
with its normal
station
and CO line assignments,
and the dedi-
cated telephone
will become
inoperative
again.