Strata CTX Configuration

Worksheet 4: Page/MOH/Control Relay

Worksheet 4: Page/MOH/Control Relay
Up to two BIOU interfaces can be installed to provide the following interfaces:
Main Location _______________
Feature
Page Zone Relays
Control Relays
MOH/BGM Device Interface
3
Page Outputs
1. The CTX100 processor provides one built-in control relay.
2. CTX100 and CTX 670 processors each provide one built-in MOH/BGM interface (RCA jack).
3. CTX100 processor provides one built-in 600 ohm page output. Each BIOU provides a 600 ohm and 3-watt page output on
the CTX670 only.
Worksheet 5: Strata CTX100 Cabinet Slot
Configuration
Write in the PCBs installed in each cabinet slot in the Cabinet Diagram below. Use the PCB
placement guideline below to place PCBs in the correct slots. A number of tables provide CTX100
capacities and configuration examples in this section.
ACTU
(AETS___)
(AMDS__)
(ARCS__)
(BSIS__)
For cost-effective configurations, try to fit all PCBs into the CTX100 Base Cabinet. This allows up
to 16 loop start COs by 32 DKTs, and up to 24 T1 or PRI COs by 40 DKTs.
• If loop start CO and DKT combinations are required, use CTX100-ECONOPKG (RCOU,
ADKU with common equipment) for up to four CO by eight DKTs or CTX100-ECONOTWO
(two RCOU, two ADKU with common equipment) for eight CO lines by 16 DKTs or greater.
Otherwise, use CTX100-0X8PKG.
• If more than 16 channels are required on an RDTU or RPTU, place PCB in S103.
• If 9~16 DKTs require Speaker OCA, place BDKU/BDKS PCBs in S103 if it is available.
• Place other required PCBs according to the guidelines herein.
• Consult the following tables of maximum system capacity slot configurations as guidelines for
PCB slot placement.
• Check system capacities in
limitations.
Notes
1. Always check the cabinet power factors using Worksheet 7 to make sure the installed PCBs and
telephones do not exceed the power factor limitations.
2. ACTU processor optional subassembly functions (see
Subassemblies" on page
1-26
1
2
CTX Base Cabinet Slots
S101
S102
S103
Tables 1-3~1-7
1-3). Any PCB plus its PCB subassembly can be installed in any slot
Remote Location 1___
1 BIOU
2 BIOUs
4
8
4
8
3
6
1
2
S104
S105
to confirm that the features to be used are within
"CTX100 Processor Optional
2___ 3___ 4___ 5___ 6___
Enter No. of Required BIOUs
CTX Expansion Cabinet Slots
S106
S107
Strata CTX I&M
S108
10/02