Peripheral Installation
External Speaker Unit (HESB) Options
BIOU switch,
SW600must be in
the SPO position
Notes
The 600 ohm duplex page output is
compatible with most
commercially available talkback
amplifiers. – MDFB not required.
Figure 9-23
Amplified Page/Talk-Back with HESB Interface
HESB Wall Mounting
Some applications may require that the HESB is mounted on a wall or other vertical surface.
➤
To wall mount the HESB
1. Find a suitable location on the mounting
surface for the HESB (see
2. Screw a 1.25-inch panhead wood screw into
the mounting surface.
3. Hang the HESB from the screw.
9-24
BIOU
SPT (38, BK-GN)
600Ω
Page
SPR (13, GN-BK)
Output
66 Block
25 Pair Cable
Jumper Wires:
TB1
TB2
1-2
3-4
5-6
Internal Wiring:
TBI
Voice
4
4
3
3
Door Phone
TBI
7
4
8
3
9
2
10
5
Figure
9-24).
MDFB (Rear View)
Door Phone
Talkback
Microphone
Jacketed Twisted
Pair 24 AWG
<Duplex>
MDF
Volume Control
Modular
Connector
May Be Used
6 5 4 3 2 1
Voice
12V 0V
12V 0V
HACU-120
Power
Converter
115VAC ± 10VAC to 12VDC
Figure 9-24
1
2 L1 L2
Jacketed
Twisted
Pair
24 AWG
L1 L2
1 2
1 2 3 4 5 6 7 8 9 10
6 5 4 3 2 1
Door Phone
TB2
1 2 3 4 5 6
Jumpers
HESB (Rear View)
One Wall
Mounting
Hole
1516
HESB Wall Mounting
Strata CTX I&M
TB1
5469
10/02