2.7.10 Configuration of I/O drawer ID and serial number

In some cases if the I/O drawer was previously connected to a p650 or p655 you
must configure the ID and serial number.
Using the ASMI
To perform this operation, the server must be powered on and your authority level
must be one of the following:
– Administrator (Login as
– Authorized service provider
If the AC power is not applied, then apply it now.
The drawer may power up automatically.
FRU replacement will generate a new temporary unit value in the expansion
unit control panel. Use this new value to power down the expansion drawer
without removing the power cord using
return here and continue with the next step.
On the ASMI welcome panel, specify your user ID and password, and click
Log In.
In the navigation area, expand
Enclosures
Select the unit identified by the new value in the panel of the unit you are
working on. In most cases it will appear as
hex digit, and the
Select
Enter the Power Control Network Identifier:
– 81 for 5074 and 5079 expansion units
– 89 for 5088 and 0588 expansion units
– 8A for 5094 and 5294 expansion units
– 8B for 5095 and 0595 expansion units
– 88 for 5790 expansion units
Enter the type-model from the label on the I/O unit.
Enter the serial number (also called sequence number) from the label on the
I/O unit.
Click
Do not use the browser's back button or the values will not be saved.
5
More information about Advanced System Management Interface (ASMI) can be found in 7.3,
"Advanced System Management Interface" on page 175
IBM Eserver p5 590 and 595 System Handbook
54
5
to set the configuration ID
Admin
.
y's
are any value.
change settings
.
Save Setting
to complete the operation.
)
powering off an expansion unit
System Configuration
and click
TMPx.yyy.yyyyyyy
. Then
Configure I/O
where x is a