System & Station
Program *41 for DK424 – T1 Assignment Series (Part 1)
Notes
You must cycle system power or run Program 91-2 to transfer Program
41-2 data from
temporary memory to working memory. Turn system power OFF (five seconds) and ON after
running Program
41-2.
Always install RDTU PCBs that have Tie or DID channels in slot numbers that are higher than
station and Attendant Console PCB slot numbers whenever possible. Each Tie or DID line
installed uses a station port in software (see the Configuration worksheets for Tie/DID
configuration in the Strata DK Installation and Maintenance Manual).
Program *41-2 Overview
RDTUs provide 8, 16, or 24 channels as set in Program 03. Each channel can operate
independently as CO lines (ground start or loop start), Tie lines (Wink or Immediate Start), or DID
lines (Wink or Immediate Start). Assign the number of channels for each RDTU with Program 03.
Important!
Program *41-3
Initialized Default:
ÃÆ
Æ
!
RDTU No.
1
PAD Code
Program *41-3 Overview
The transmission path of each RDTU can be set for one of several pad settings:
Code
Enter 1
Enter 2
Enter 3
Enter 4
3-124
Program 91-2 must be run or System Power must be momentarily turned OFF (five
seconds) then ON for Program * 41-2 to take effect.
–
T1 Span Transmit Level Pad Assignments
5 (-6dB)
"
Tx
#
Cyq
Tx
"
SELECT = 3
Enter the RDTU being
programmed (1~8).
2
3
4
5
Decibel Level
+6 decibel (dB) padding
+3 dB
0 dB
-3 dB
Cyq
Tx
Æ Æ Cyq
Enter one of the following pad codes for the
transmission of path:
1 = +6 dB pad
2 = +3 dB pad
3 = 0 dB pad
6
7
8
4 = -3 dB pad
5 = -6 dB pad (Initialized: PAD_S = 5)
6 = -9 dB pad
7 = -12 dB pad
8 = -15 dB pad
Code
Enter 5
-6 dB (initialized setting)
Enter 6
-9 dB
Enter 7
-12 dB
Enter 8
-15 dB
Tx
Æ Æ Cyq
Decibel Level
Strata DK Programming 5/99