Purpose
Operation test, check
Function (Content)
Used to adjust the width detection level of the
multi-purpose tray paper width detector.
Section
Paper feed
Item
Operation
Operation/Procedure The multi-purpose tray size is adjusted.
1) Extend the guide to the MAX. position.
Select 1 and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
2) Move the guide to MIN. position.
Select 2 and press START.
When COMPLETE is displayed,
the adjustment is completed.
If ERROR is displayed in procedures 1) - 2),
repeat the adjustment again.
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT. SELECT 1-2,AND PRESS
START.
1.MAX POSITION
2.MIN. POSITION
When "1" is selected,
Press [CUSTOM SETTING] key.
press [START] key.
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MAX. POSITION ... COMPLETE(or "ERROR")
When "2" is selected,
press [START] key.
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MIN. POSITION ... COMPLETE (or "ERROR")
1
Press [CUSTOM SETTING] key.
AR-M350 SIMULATIONS 10-33
Main code 41
41-1
Purpose
Operation test, check
Function (Content)
Used to check the operations of the document
size sensor and the related circuit.
(The operation of the document size sensor can
be monitored on the LCD display.)
Section
Other
Item
Operation
Operation/Procedure The OC document sensor is checked.
SIMULATION 41-1
PD SENSOR CHECK..
OCSW
PD1
PD2
PD3
PD4
(The detected sensor is highlighted.)
<List of display values>
OCSW
Original cover state
Open : Normal display
Close : Highlighted
PD1 ~ 7
Document sensor state
No document : Normal display
Document loaded : Highlighted
41-2
Purpose
Adjustment
Function (Content)
Used to adjust the detection level of the
document size sensor.
Section
Other
Item
Operation
Operation/Procedure The OC document sensor is adjusted.
1) Open the original cover. Press 1 without an
original. Press START, and COMPLETE is
displayed. Press CUSTOM SETTING to
return to the initial screen.
2) Place an A3 (or WLT) paper in the initial
screen. Select 2 and press START.
When COMPLETE is displayed,
the adjustment is completed.
If ERROR is displayed in procedures 1) - 2),
repeat the adjustment again.
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.)
1. NO ORIGINAL
2. A3 ORIGINAL
When "1" is selected,
press [START] key.
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ... COMPLETE (or " ERROR at
A3 ORIGINAL ... INCOMPLETE
When "2" is selected,
press [START] key.
(In case of an error)
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ... COMPLETE
A3 ORIGINAL ... COMPLETE (or " ERROR at
PD5