22. INITIALIzATION OF THE SETTING DATA
1
2
1. When you carry out the aforementioned operation, the neutral position correction value for the
pedal sensor is also initialized. It is therefore necessary to carry out automatic correction of the
pedal sensor neutral position before using the sewing machine.
(Refer "20. AUTOmATIC COmPENSATION OF NEUTRAL POINT OF THE PEDAL SENSOR" p.18.)
2. When you carry out the aforementioned operation, the machine-head adjustment values are also
initialized. It is therefore necessary to carry out adjustment of the machine head before using the
sewing machine.
(Refer "5. ADjUSTING THE mACHINE HEAD" p.3.)
3. Even when this operation is performed, the sewing data set by the operation panel cannot be
initialized.
23. CHECKING PROCEDURE OF THE ERROR CODE
1
2
3
- 9 -
All contents of functon settng can be returned to the
standard set values.
) Pressng all swtches 1 , 2 and 3 , turn ON the
power swtch.
2) "
" s dsplayed on ndcator wth a "blp" to
start ntalzaton.
3) The buzzer sounds after approxmately one
second (sngle sound three tmes, "blp", "blp",
and "blp"), and the settng data returns to the
standard settng value.
Do not turn OFF the power on the way of
initializing operation. Program of the main
unit may be broken.
4) Turn OFF the power swtch and turn ON the
power swtch agan to return to the normal mode.
) Turn ON the power swtch wth swtch 1 held
pressed.
2) The latest error number s dsplayed on ndcator
wth blp.
3) Contents of previous errors can be checked by
pressng swtch 2 .
(When the procedure has reached the end, two alarm
sounds n sngle tone wll be heard, "blp" "blp".)