1. INSTALLING THE CONTROL PANEL
WARNING :
To prevent personal injury caused by abrupt start of the sewing machine, carry out the work after
turning OFF the power switch and ascertaining that the motor has completely stopped.
1
) Remove sde plate setscrews 1 from the sde plate.
2) Install control panel 2 on the machne head usng screws 5 , flat washers 3 and rubber seat 4 sup-
pled wth the control panel as the accessores.
1. DDL-9000B (Not provided with AK) is given as an example of installing procedure.
2. Screw to install the panel changes according to the machine head used. Refer to Table 1 and
confirm the kind of screw.
< The relation between the respective machine heads and the positions of installing hole of the bracket are as described in the table. >
1
2
3
4
2. CONNECTING THE CORD
A
Table 1
DDL-9000A
DDL-9000B
LH-3500A
5
6
1
-  -
2
4
3
5
Installng hole
1 - 5
M5 X 2
(Provded wth AK)
M5 X 4
1 - 5
(Not provded wth AK)
M5 X 2
2 - 5
M5 X 4
) Pass cord 1 of the control panel through hole A
n the machne table route t to the undersde of
the table.
2) As for the connecton of the connector, refer to
the Instructon Manual for the control box.
Screw
Screw suppled wth panel
as accessores
Sde plate setscrew
Screw suppled wth panel
as accessores
Sde plate setscrew