Switching Over To The Standby Redundant Management Module - HP ProCurve 9304M Installation And Configuration Manual

Routing switches
Hide thumbs Also See for ProCurve 9304M:
Table of Contents

Advertisement

USING THE WEB MANAGEMENT INTERFACE
NOTE: This procedure applies only to synchronization of the boot code and running-config. To change
automatic synchronization of other software, use the CLI procedure above.
1. Log on to the device using a valid user name and password for read-write access. The System configuration
dialog is displayed.
2. Select the Redundant link to display the following panel.
3. To enable automatic synchronization of the boot code, select the checkbox next to Boot Flash.
4. To change the synchronization interval for the running-config, enter the new value in the Running
Configuration Interval field. To disable automatic synchronization of the running-config, enter 0 in the field.
5. Select the checkbox next to Boot Flash.
NOTE: Do not click the Synchronize Boot Flash Now button unless you want the active module to
immediately copy its boot flash image to the standby module.
6. Click the Apply button to send the configuration change to the active module's running-config file.
7. If you want the change to remain in effect following the next system reload, select the Save link to save the
configuration change to the active redundant management module's startup-config file. (The change is
automatically sent to the standby module when the active module's system-config file is copied to the standby
module.)

Switching Over to the Standby Redundant Management Module

If you reload the software using the reload command, the behavior of the management modules is the same as
when you power the system on. The system selects the active module based on the slot you specified or based
on the lower slot number if you did not specify a slot. Then both redundant management modules load their own
boot code and load the active redundant management module's flash code (system software) and system-config
file.
If you do not want to reload the system but you instead want to force the system to switch over to the standby
module (and thus make it the active redundant management module), use one of the following methods.
USING THE CLI
To switch over to the other redundant management module, enter a command such as the following:
HP9300# reset 2
Syntax: reset <slot-num>
Using Redundant Management Modules
3 - 15