Table 10.5: CLI Display of VSRP VRID or VLAN Information (Continued)
This Field...
Administrative-status
Advertise-backup
Preempt-mode
save-current
Note: For the following fields:
Configured – indicates the parameter value configured on this device.
Current – indicates the parameter value received from the Master.
Unit – indicates the formula used tor calculating the VSRP priority and the timer scales in effect for the
VSRP timers. A timer's true value is the value listed in the Configured or Current field divided by the scale
value.
priority
hello­interval
Displays...
The administrative status of the VRID. The administrative status can
be one of the following:
disabled – The VRID is configured on the interface but VSRP or
VRRPE has not been activated on the interface.
enabled – VSRP has been activated on the interface.
Whether the device is enabled to send VSRP Hello messages when it
is a Backup. This field can have one of the following values:
disabled – The device does not send Hello messages when it is
a Backup.
enabled – The device does send Hello messages when it is a
Backup.
Whether the device can be pre-empted by a device with a higher
VSRP priority after this device becomes the Master. This field can
have one of the following values:
disabled – The device cannot be pre-empted.
enabled – The device can be pre-empted.
The source of VSRP timer values preferred when you save the
configuration. This field can have one of the following values:
false – The timer values configured on this device are saved.
true – The timer values most recently received from the Master
are saved instead of the locally configured values.
The device's preferability for becoming the Master for the VRID.
During negotiation, the Backup with the highest priority becomes the
Master.
If two or more Backups are tied with the highest priority, the Backup
interface with the highest IP address becomes the Master for the
VRID.
The number of seconds between Hello messages from the Master to
the Backups for a given VRID.
Configuring Metro Features
10 - 35