2. Functions for FTX, FVXS Series

2.1

Airflow Direction Control

Power-Airflow
The large flap sends a large volume of air downward to the floor and provides an optimum control in
(Dual) Flap(s)
cooling, dry and heating operation.
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
Heating
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
Louvers
comfortable air distribution.
Auto-Swing
The following tables explain the auto-swing process for cooling, dry, heating and fan:
FTX series
Part 4 Functions and Control
Cooling/Dry
09/12
class
50°
(R21048)
15 class
15°
30°
70°
55°
(R21651)
15°
18/24
class
25°
50°
60°
(R9303)
Flap (up and down)
Heating
15°
65°
(R21049)
10°
20°
35°
80°
65°
(R21652)
15°
30°
40° 75°
70°
(R9304)

Functions for FTX, FVXS Series

Louver
(right and left)
Fan
65°
(R21050)
25°
80°
65°
(R21653)
25°
75°
70°
(R9306)
(R9305)