Air Filters Si041553EB 1. Air Filters Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the air filters. The air filter is not marked Front panel for difference between the Open the front panel.
Si041553EB Front Panel 2. Front Panel Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Release the left and Shaft Left right shafts. (R24362) Shaft Right (R24285) Remove the front panel.
Front Grille Si041553EB 3. Front Grille Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the 3 screws of the front grille. Front grille (R21497) Unfasten the 3 hooks at The convex marks (…) on Hook the top.
Si041553EB Horizontal Blades 4. Horizontal Blades Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Release the center Center shaft shafts of the upper horizontal blade while bending the blade slightly.
Electrical Box / Swing Motor Si041553EB 5. Electrical Box / Swing Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Disconnect the The service cover can be connecting wire.
Page 9
Si041553EB Electrical Box / Swing Motor Step Procedure Points Pull out the indoor heat Be careful not to lose the clip exchanger thermistor. of the thermistor. Clip Indoor heat exchanger thermistor (R11268) When reassembling, pass the indoor heat exchanger (R21505) thermistor behind the green earth/ground wire.
Page 10
Electrical Box / Swing Motor Si041553EB Step Procedure Points Disconnect the [S200]: fan motor Right view connector [S200]. Release the harnesses from the 4 hooks and [S200] the groove. Groove Hook Hook (R24363) Disconnect the [S6]: swing motor connector [S6]. Release the harnesses from the 2 hooks and [S6]...
Page 11
Si041553EB Electrical Box / Swing Motor Step Procedure Points Unfasten the hook at the front, then slightly lift the electrical box upward. Remove the electrical box. Hook (R21522) When reassembling, make Bottom frame Hook sure that the 2 hooks are securely fastened to the bottom frame.
PCBs Si041553EB 6. PCBs Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the control PCB. White Earth/ground wire Earth/ground wire Black Disconnect all the 4 Black White Red terminals.
Page 13
Si041553EB PCBs Step Procedure Points Unfasten the 5 hooks Hook and remove the control PCB. (R21515) Hook When reassembling, fit the control PCB to the 3 Control PCB projections. Projections (R24274) 2. Remove the filter PCB. [S100]: terminal board Disconnect the connector [S100].
Page 14
PCBs Si041553EB Step Procedure Points 3. Remove the display PCB. Left view Release the harness of the signal receiver unit from the 3 hooks. Hook (R24364) Signal receiver unit Unfasten the 2 hooks of When reassembling, make the signal receiver unit. sure to fit the bottom of the signal receiver unit before fastening the 2 hooks.
Si041553EB Indoor Heat Exchanger 7. Indoor Heat Exchanger Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. In pump-down work, be sure to stop the compressor before disconnecting the refrigerant pipe. If the refrigerant pipe is disconnected with the compressor operating and the stop valve open, air may be sucked in and may generate an over-pressure in refrigeration cycle, thus resulting in pipe rupture or accidental injury.
Page 16
Indoor Heat Exchanger Si041553EB Step Procedure Points 2. Remove the indoor heat exchanger. Detach the indoor unit from the installation plate. (R21526) Unfasten the 2 hooks Piping fixture and remove the piping fixture on the back of the indoor unit. Hook (R21527) Slightly pull out the...
Page 17
Si041553EB Indoor Heat Exchanger Step Procedure Points Unfasten the 2 hooks When reassembling the Indoor heat exchanger on the right side and lift indoor heat exchanger, up the indoor heat make sure that the 2 hooks exchanger. are fastened. Hook (R21530) Removal Procedure...
Fan Rotor / Fan Motor Si041553EB 8. Fan Rotor / Fan Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the screw of Right side plate the right side plate.
Page 19
Si041553EB Fan Rotor / Fan Motor Step Procedure Points Pull out the fan motor from the fan rotor. Motor cover Unfasten the 2 hooks of the motor cover. Hook (R21534) Disassemble the fan Fan motor cover (body) motor. Bearing rubber cushion Rubber cushion Fan motor...
Fan Guards / Vertical Blade ASSYs Si041553EB 9. Fan Guards / Vertical Blade ASSYs Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the fan guards. The fan guards are not Fan guard marked for difference...
Page 21
Revision History Month / Year Version Revised contents 05 / 2015 Si041553E First edition 01 / 2016 Si041553EA Model addition: FTX15NMVJU 12 / 2016 Si041553EB Model addition: FTK24P5VL, FTX24N5VL, FTH24P5VL...
Page 22
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.