D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Framing or finishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Mantels - Combustible or Painted Surfaces
Note: All measurements in inches.
4
3
2-1/2
5
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
Note: Measurement is taken from top of the
opening, NOT the top of the fireplace.
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible or Painted Surfaces
Mantels - Non-Combustible
Note: All
measurements
in inches.
4
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6000CLX)
= 35-1/2 IN. (8000CLX)
Note: Measurement is taken from top of the opening,
NOT the top of the fireplace.
Figure 5.4
Minimum Vertical and Maximum Horizontal
Dimensions- Non-Combustible
22
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AN • 2/16
TO CEILING
18
12
11
10
9
8
25
7
19
6
18
5
17
16
15
14
13
12
11
10
TO CEILING
18
12
11
10
9
8
25
7
19
6
18
5
17
16
15
14
13
12
Mantel Legs or Wall Projections
FIREPLACE OPENING
32
Combustible or Painted Surfaces
A
B
Non-Combustible
A
B
Figure 5.5 Clearances to Mantel Legs or Wall Projections
32
TOP VIEW
A
MANTEL LEG OR WALL PROJECTIONS
A
If
minimum is ____, then
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Inches
62
87
113
Millimeters
1
2
3
Inches
25
51
76
Millimeters
A
If
minimum is ____, then
0 thru 5-7/16
6-7/16
Inches
0-138
Millimeters
4
Inches
102
Millimeters
(Acceptable on both sides of opening.)
INTERIOR WALL
B
B
maximum is_____.
138
164
189
4
5
102
127
B
maximum is_____.
7-7/16
164
189
5