Rear Vent - Heat & Glo 6000CLX-IPI-T Owner's Manual

Hide thumbs Also See for 6000CLX-IPI-T:
Table of Contents

Advertisement

Figure 9.6 To attach the first section of vent pipe, make
sure to use the fiberglass gasket in the manual bag to seal
between the first vent component and the outer fireplace
wrap. Caulk with a minimum of 300ºF continuous exposure
rating may be used to hold the part in place.
Secure the first section of venting to the fireplace by screw-
ing through the two straps left over from cutting the seal
cap strap in step 2.
B. Rear Vent
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
Figure 9.7 Fold the tabs toward the center of the seal
cap (90º) and remove the insulation gasket.
Figure 9.8 Cut the metal retaining band and fold the
sides out.
40
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. AN • 2/16
Figure 9.9 Fold the center parts of the retaining band out
and use to remove the seal cap.
NOTICE: Once the seal cap has been removed it CANNOT
be reattached.
Figure 9.10 Discard the vent cap, remove and discard
the insulation basket.