Battery Storage; Battery Care - Toro ProForce 44538 Service Manual

Hide thumbs Also See for ProForce 44538:
Table of Contents

Advertisement

Battery Storage

If the machine will be stored for more than 30 days:
1. Remove the battery from the machine and charge it
fully (see Battery Service).
2. Either store battery on a shelf or on the machine.
3. Leave battery cables disconnected if the battery is
stored on the machine.

Battery Care

1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
CAUTION
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a well
ventilated place so gasses produced while
charging can dissipate. Since the gases are ex-
plosive, keep open flames and electrical sparks
away from the battery; do not smoke. Nausea
may result if the gases are inhaled. Unplug char-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
IMPORTANT: Do not remove battery fill caps while
cleaning.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
case clean because a dirty battery will discharge slowly.
A. Clean battery by washing entire case with a solu-
tion of baking soda and water. Rinse with clear water.
B. Coat battery posts and cable connectors with
Battery Terminal Protector (Toro Part No. 107--0392)
or petroleum jelly to prevent corrosion.
Electrical System
4. Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
5. To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service).
3. Battery cables must be tight on terminals to provide
good electrical contact. Tighten nuts that secure battery
cables from 10 to 15 ft- -lb (14 to 20 N- -m).
Connecting battery cables to the wrong bat-
tery post could result in personal injury and/or
damage to the electrical system.
4. If corrosion occurs at battery terminals, disconnect
cables. Always disconnect negative (--) cable first.
Clean clamps and terminals separately. Reconnect
cables to battery with positive (+) cable first. Coat bat-
tery posts and cable connectors with Battery Terminal
Protector (Toro Part No. 107--0392) or petroleum jelly to
prevent corrosion.
5. Periodically (at least every 50 operating hours)
check battery electrolyte level. Check electrolyte level
every 30 days if machine is in storage.
6. Maintain battery cell level with distilled water. Do not
fill battery cells above the fill line.
Page 4 - - 22
CAUTION
ProForce Debris Blower

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: