Fuse

The ProForce Debris Blower uses a 15 amp fuse for cir-
cuit protection. The fuse holder for this fuse is located
next to the engine (Fig. 8).
The engine wire harness includes a 30 amp fuse for cir-
cuit protection. The engine fuse is located near the start-
er motor (Fig. 9).
Testing
1. Make sure that ignition switch is OFF.
2. To prevent unexpected machine operation, discon-
nect the negative battery cable from the battery terminal
(see Battery Service in the Service and Repairs section
of this chapter). Position disconnected negative cable
away from the negative battery terminal.
3. Press latch that retains fuse holder cover and raise
cover to access fuse.
4. With the use of a multimeter (ohms setting), check for
continuity between fuse terminals by using test ports at
top of fuse. Fuse should have continuity between fuse
terminals.
5. If necessary, remove and replace fuse.
6. Connect negative battery cable to negative battery
terminal. Tighten nut that secures battery cable from 10
to 15 ft- -lb (14 to 20 N- -m). Make sure that battery cover
is secured.
ProForce Debris Blower
1
1. Wire harness
2. Fuse
1. Engine fuse
Page 4 - - 11
3
2
Figure 8
3. Fuse cover
1
Figure 9
2. Starter motor
Electrical System