Xantrex 807-1055 Owner's Manual page 54

Freedom hfs inverter/chargers
Hide thumbs Also See for 807-1055:
Table of Contents

Advertisement

Freedom HFS IC Owners Guide.book Page 40 Friday, September 11, 2015 2:54 PM
Specifications
NOTE: These are inverter specifications.
DC Input
Operating voltage range for all models
Safe non-operating voltage range
Nominal voltage for all models
Nominal current at full load
AC Output
Output voltage range
Continuous power
Continuous current
Surge power
Max short-circuit current
Frequency
GFCI protection for 120VAC models only
Wave shape
Peak efficiency
Full load efficiency
Other
No load input power (producing output voltage)
Off mode current draw
40
Freedom HFS 1055 models
10.5–16.5 VDC (low limit)
11.8–16.5 VDC (mid limit)
12.1–16.5 VDC (high limit)
0–24 VDC
12.5 VDC
92 ADC
Freedom HFS 1055 models
110–125 VAC
1.0kW @ 25 °C
8.3 A
2000 W
55 A peak
60 Hz
Yes
True Sine Wave
87%
82%
Freedom HFS 1055 models
10W
4mA
Freedom HFS 2055 models
10.5–16.5 VDC (low limit)
11.8–16.5 VDC (mid limit)
12.1–16.5 VDC (high limit)
0–24 VDC
12.5 VDC
200 ADC
Freedom HFS 2055 models
110–125 VAC
2.0kW @ 25 °C
16.9 A
4000 W
55 A peak
60 Hz
Yes
True Sine Wave
87%
82%
Freedom HFS 2055 models
10W
4mA
Freedom HFS Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

807-2055-02807-1055-02807-2055807-2055-01