Checking Battery Status
During inverter operation, you can check the battery status by
pressing the Select button until the Battery Voltage LED (or Battery
Current LED) illuminates. The battery voltage (or battery current)
appears in the three-digit LED display screen when the Battery
Voltage LED (or Battery Current LED) illuminates.
The normal operating battery voltage range is between 11 and
15 volts.

Checking Output Power

During inverter operation, you can check how much power
(displayed in kW) the Freedom HFS is supplying to the connected
loads by pressing the Select button until the Output Power LED
illuminates.

Operating Several Loads at Once

If you are going to operate several loads from the Freedom HFS,
turn them on one at a time after you have turned the inverter on.
Turning loads on separately helps to ensure that the inverter does
not have to deliver the starting current for all the loads at once, and
will help prevent an overload shutdown.
975-0727-01-01
Turning the Audible Alarm ON or OFF
The Freedom HFS's audible alarm can be turned ON or OFF. See
"To adjust the alarm setting:" on page 13.
Any warnings such as fault conditions or imminent shutdown are
both displayed on the display panel's screen and sounded on the
alarm speakers.
It is not possible to turn OFF the screen and prevent it from
displaying error codes but it is possible to turn OFF the audible
alarm.
The alarm setting will reset to its default setting when the
NOTE:
Freedom HFS's Inverter Power button is turned OFF then turned
ON again.