Operating in Shore Power Mode

The Freedom HFS operates in shore power mode when an AC
source (a generator or utility power) is present at the AC input
terminals. When the AC source is within operating range, the
Freedom HFS unit bypasses inverter mode and powers the
appliances connected to the unit. See "Transitioning from Inverter
Mode to Shore Power" on page 22.
The Freedom HFS also automatically charges the battery bank that
is connected while in shore power mode. See "Battery Charging" on
page 25.
The Green status LED lights up to indicate that the Freedom HFS is
using utility (or generator) power and the battery is full. A flashing
Green LED indicates that the unit is charging the battery.
When shore power is present, AC power automatically passes
through the Freedom HFS. Pressing the Inverter Power button on
the display panel does not interrupt the supply of shore power.
Shore Power mode supersedes Inverter operation.
When the Freedom HFS's Inverter Power button is turned ON and
the AC source is outside the operating range or is disconnected, the
transfer switch automatically switches to inverter operation. See
"Transitioning from Shore Power to Inverter Mode" on page 22.