Freedom Inverter/Charger Configuration
To adjust the low battery shutdown setting:
By default the low battery shutdown voltage setting is set to
Low ("").
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. For example, "" is for a low shutdown
voltage setting.
low setting = 10.5 V
middle setting = 11.8 V
high setting = 12.1 V
4.
Continue pressing the Select button to cycle through the three –
"", "" and "" settings until you reach the desired
setting.
5.
Press and hold the Select button for five seconds to make the
setting permanent.
14
To adjust the battery type setting:
By default the battery type setting is set to Flooded ("").
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. For example, "" is for a flooded battery
type setting.
Flooded
AGM
Gel
Custom
4.
Continue pressing the Select button to cycle through the four –
"", "", "", and "" settings until you reach the
desired setting.
5.
Press and hold the Select button for five seconds to make the
setting permanent.