Freedom HFS IC Owners Guide.book Page 14 Friday, September 11, 2015 2:54 PM
Freedom Inverter/Charger Configuration
To adjust the low battery shutdown setting:
By default the low battery shutdown voltage setting is set to
Low ("").
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. For example, "" is for a low shutdown
voltage setting.

low setting = 10.5 V

middle setting = 11.8 V

high setting = 12.1 V
4.
Continue pressing the Select button to cycle through the three –
"", "" and "" settings until you reach the desired
setting.
5.
Press and hold the Select button for five seconds to make the
setting permanent.
14
To adjust the battery type setting:
By default the battery type setting is set to Flooded ("").
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. For example, "" is for a flooded battery
type setting.

Flooded

AGM

Gel

Custom
4.
Continue pressing the Select button to cycle through the four –
"", "", "", and "" settings until you reach the
desired setting.
5.
Press and hold the Select button for five seconds to make the
setting permanent.
Freedom HFS Owner's Guide