Xantrex 807-1055 Owner's Manual page 34

Freedom hfs inverter/chargers
Hide thumbs Also See for 807-1055:
Table of Contents

Advertisement

Freedom HFS IC Owners Guide.book Page 20 Friday, September 11, 2015 2:54 PM
Operating in Inverter Mode
Status LED During Inverter Operation
The following summarizes the behavior of the Status LED during
Inverter operation.
Table 2 Status LED during Inverter Operation
Status
Display
LED
Screen
Condition
Solid
.
Select button is pressed to display Input
YELLOW
(where 12.8 is
Battery Voltage.
an example of
The Input Battery Voltage LED lights up.
battery
Value in display screen is shown as Volts.
voltage)

Select button is pressed to display Input
(where 11 is
Current.
an example of
The Input Current LED lights up.
current)
Value in display screen is shown as Amps.
.
Select button is pressed to display Output
(where 0.85 is
Power.
an example of
The Output Power LED lights up.
output power
Value in display screen is shown as
in Kilowatts)
Kilowatts.
20
Table 2 Status LED during Inverter Operation
Status
Display
LED
Screen
Condition
Solid RED through
Fault condition detected and AC output

power is not available. For details, see
Table 5, "Error Codes Displayed on the
Display Panel Screen" on page 30.
through
Warning condition detected while AC

output power is still available.
See Table 5, "Error Codes Displayed on the
Display Panel Screen" on page 30.
Off
Off
Inverter operation is OFF.
Off (or
.
No communication between the Freedom
Yellow)
HFS and the Display Panel because the
battery voltage was too low to start the
Inverter.
Freedom HFS Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

807-2055-02807-1055-02807-2055807-2055-01

Table of Contents