Table 5 Error Codes Displayed on the Display Panel Screen
Error Code
Condition
Low battery voltage detected
depending on setting, see
"Operating Limits" on page 23.
AC output overload warning
Over-temperature warning
not used
not used
High battery voltage (> 15.5 V) AC shore power
Battery is bad or external DC
load is connected to the battery.
975-0727-01-01
Mode
Action
Inverting
•
Check battery status and recharge if necessary.
•
Check for proper DC cable sizing.
•
Check for loose connections and tighten if necessary.
Inverting
•
Reduce the loads connected to the AC outlet of the unit.
Inverting
•
Reduce the loads connected to the AC outlet of the unit.
•
Check that the ventilation grille is not blocked.
•
Check for ambient temperature and move the unit to a cooler
location whenever possible.
•
Check for external charging sources, such as an over voltage
alternator, and disconnect if necessary.
•
Confirm that the external charging source is not the cause. The error
may be caused by the internal battery charger system. Call Xantrex
for support.
Check the battery bank.
AC shore power
•
NOTE: The battery voltage did not rise above 5 volts DC after 1
minute or 10 volts DC after 15 minutes.
•
Check that the external DC load current consumption is below the
charging current setting.
•
Disconnect the DC load or increase the charger current setting.