Summary of Contents for Xantrex 807-1055

  • Page 1 Freedom HFS IC Owners Guide.book Page i Friday, September 11, 2015 2:54 PM Owner’s Guide Product image shown may vary from actual product. See features for comparisons. Freedom HFS Inverter/Chargers Model Product Numbers 807-1055 807-1055-02 807-2055 807-2055-01 807-2055-02...
  • Page 2 Freedom HFS IC Owners Guide.book Page ii Friday, September 11, 2015 2:54 PM...
  • Page 3: Contact Information

    To view, download, or print the latest revision, visit the website shown under Contact Freedom HFS 1055 (1000-watt) Models: Information. 807-1055 (Freedom HFS 1055 120VAC Standard Model) 807-1055-02 (Freedom HFS 1055 120VAC EMS Model) Freedom HFS 2055 (2000-watt) Models: 807-2055 (Freedom HFS 2055 120VAC Standard Model)
  • Page 4 Purpose Related Information The purpose of this Owner’s Guide is to provide explanations and You can find more information about Xantrex products and services at procedures for operating, maintaining, and troubleshooting a Freedom HFS www.xantrex.com. Sine Wave Inverter/Charger for Recreational, Fleet Vehicle, or Marine installations.
  • Page 5: Important Safety Instructions

    Freedom HFS IC Owners Guide.book Page iii Friday, September 11, 2015 2:54 PM Important Safety Instructions IMPORTANT: R ’ EAD AND SAVE THIS WNER UIDE FOR FUTURE REFERENCE DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. This guide contains important safety instructions for the Freedom HFS Sine Wave Inverter/Charger that must be followed during operation and troubleshooting.
  • Page 6: Safety Information

    Freedom HFS IC Owners Guide.book Page iv Friday, September 11, 2015 2:54 PM Safety Information Before using the inverter/charger, read all instructions and Do not expose this unit to rain, snow, or liquids of any type. This cautionary markings on the unit, the batteries, and all appropriate product is designed for indoor use only.
  • Page 7 Freedom HFS IC Owners Guide.book Page v Friday, September 11, 2015 2:54 PM HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FIRE AND EXPLOSION HAZARD FLASH • Unit’s components may produce arcs or sparks. • Do not install near batteries, in machinery space, or in an area in •...
  • Page 8 Freedom HFS IC Owners Guide.book Page vi Friday, September 11, 2015 2:54 PM NOTES: Follow these instructions and those published by the battery ELECTRICAL SHOCK AND FIRE HAZARD manufacturer and the manufacturer of any equipment you intend to use • Do not open.
  • Page 9: Precautions When Working With Batteries

    Freedom HFS IC Owners Guide.book Page vii Friday, September 11, 2015 2:54 PM Precautions When Working With Batteries If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and get medical attention IMPORTANT: Battery work and maintenance must be done by qualified...
  • Page 10 Freedom HFS IC Owners Guide.book Page viii Friday, September 11, 2015 2:54 PM Precautions When Preparing to Charge Precautions When Placing the Inverter/Charger EXPOSURE TO CHEMICALS AND GASES HAZARD FIRE AND BURN HAZARDS • Make sure the area around the battery is well ventilated. Do not install the inverter/charger or any part of its supplied wiring in •...
  • Page 11 Freedom HFS IC Owners Guide.book Page ix Friday, September 11, 2015 2:54 PM Regulatory FCC Information to the User The Freedom HFS Sine Wave Inverter/Charger is certified to appropriate This equipment has been tested and found to comply with the limits for a US and Canadian standards.
  • Page 12 Freedom HFS IC Owners Guide.book Page x Friday, September 11, 2015 2:54 PM...
  • Page 13: Table Of Contents

    Freedom HFS IC Owners Guide.book Page i Friday, September 11, 2015 2:54 PM Contents Important Safety Instructions ..................iii Introduction .
  • Page 14 Freedom HFS IC Owners Guide.book Page ii Friday, September 11, 2015 2:54 PM...
  • Page 15: Introduction

    • one display panel mounting bezel (not shown) • one set of lock washers and nuts (not shown) NOTE: If any of the items are missing, contact Xantrex or any authorized Xantrex dealer for replacement. See “Contact AC compartment communications...
  • Page 16: Key Features

    If so, the Freedom HFS automatically shuts down when the maximum operating limit is exceeded. a.Freedom HFS 1055 120VAC (PN: 807-1055) and Freedom HFS 1055 120VAC EMS (PN: 807-1055-02). b.,Freedom HFS 2055 120VAC (PN: 807-2055), Freedom HFS 2055 120VAC Truck (PN: 807-2055-01), and Freedom HFS 2055 120VAC EMS (PN: 807- c.Assuming the inverter/charger is connected to a battery source with an adequate...
  • Page 17 However, some batteries which have been left uncharged for days can become severely damaged thus, recharging is futile. b.Available on the Freedom HFS 1055 120VAC EMS model (PN: 807-1055-02) and Freedom HFS 2055 120VAC EMS model (PN: 807-2055-02). The inverter/charger features a 20-amp fused and switched output voltage supplied from the inverter/char- ger's positive terminal.
  • Page 18: Features

    Freedom HFS IC Owners Guide.book Page 4 Friday, September 11, 2015 2:54 PM Features Front Panel (Standard Models) Table 1 lists the default settings for the Freedom HFS system. You may record your settings in the right-hand column after you have configured the Freedom HFS.
  • Page 19 Freedom HFS IC Owners Guide.book Page 5 Friday, September 11, 2015 2:54 PM Features Front Panel (Truck Model) Front Panel (EMS Models) Ignition FREEDOM HFS Power Enable Cont rol FREEDOM HFS FREEDOM HFS Rem ote STATUS Utility Battery Select FREEDOM HFS 1800 EMS Fault Feature Description...
  • Page 20 Freedom HFS IC Owners Guide.book Page 6 Friday, September 11, 2015 2:54 PM Features Rear Panel (EMS Models) Rear Panel (All Other Models) Freedom HFS 1055 shown Feature Description Feature Description Negative DC cabling terminal that is pre-connected to an 18-inch (0.45m) Negative DC cabling terminal connects to the negative terminal of the battery cable with an Anderson...
  • Page 21 Remote jack is used for connecting the Display panel that ships with the inverter mode ON or OFF. See page 16 for additional information. Freedom HFS 1055 120VAC EMS (PN: 807-1055-02) and Freedom HFS 2055 120VAC EMS (PN: 807-2055-02). Each shipment comes with a 25-foot Three-digit LED display screen shows status information and fault codes.
  • Page 22 Freedom HFS IC Owners Guide.book Page 8 Friday, September 11, 2015 2:54 PM Features Side Panel (All Models) Feature Description 20 A supplementary protector provides overload protection for the GFCI receptacles. In a hard wired installation, the supplementary protector does not protect output wiring.
  • Page 23: Freedom Inverter/Charger Configuration

    Freedom HFS IC Owners Guide.book Page 9 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration Setting Battery Types on the Main Unit Viewing Inverter/Charger Information You can attach different types of lead-acid batteries to the Freedom The LED screen displays inverter/charger information as well as HFS.
  • Page 24 Freedom HFS IC Owners Guide.book Page 10 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration Info and Setting LED Screen Info and Settings LED Inverter Mode  or  or none Setting  Alarm Setting  or  none Low Voltage Setting ...
  • Page 25 Freedom HFS IC Owners Guide.book Page 11 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration Adjusting Feature Settings The Power and Select buttons can be used to: To cycle through the various feature settings: • change the charging current setting Press and hold the Inverter Power button for five seconds to enter the feature settings mode.
  • Page 26 Freedom HFS IC Owners Guide.book Page 12 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration To change the charger’s charging current setting: To change the inverter mode setting: By default the charging current is set to . By default the inverter mode is set to ON (“”). Press and hold the Inverter Power button for five seconds.
  • Page 27 Freedom HFS IC Owners Guide.book Page 13 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration To adjust the alarm setting: NOTE: Inverter mode ON (“”) will put the inverter on standby with By default the alarm is set to ON (“”).. the power save feature.
  • Page 28 Freedom HFS IC Owners Guide.book Page 14 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration To adjust the low battery shutdown setting: To adjust the battery type setting: By default the low battery shutdown voltage setting is set to By default the battery type setting is set to Flooded (“”).
  • Page 29 Freedom HFS IC Owners Guide.book Page 15 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Configuration To adjust the custom battery voltage setting: Press the Select button to cycle through the available range of values (12.0 to 17.0 in 0.2 increments) until you reach the NOTE: This setting is possible only when the Battery Type setting desired setting.
  • Page 30: Freedom Inverter/Charger Operation

    Freedom HFS IC Owners Guide.book Page 16 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Operation Display Panel Operation Feature Description The Freedom HFS features a display panel with three-digit LED Three-digit LED display screen shows status information and detected fault codes. Upon startup, the screen shows the display to show inverter, AC source, and battery status information.
  • Page 31 Freedom HFS IC Owners Guide.book Page 17 Friday, September 11, 2015 2:54 PM Freedom Inverter/Charger Operation Feature Description Select button • During inverter operation, press the button to choose what appears in the three-digit LED display: Battery Voltage, Battery Current, or Output Power. See “To change the inverter mode setting:”...
  • Page 32: Operating In Shore Power Mode

    Freedom HFS IC Owners Guide.book Page 18 Friday, September 11, 2015 2:54 PM Operating in Shore Power Mode The Freedom HFS operates in shore power mode when an AC source (a generator or utility power) is present at the AC input terminals.
  • Page 33: Operating In Inverter Mode

    Freedom HFS IC Owners Guide.book Page 19 Friday, September 11, 2015 2:54 PM Operating in Inverter Mode The Freedom HFS is in inverter operation (operating in inverter mode) when all the following conditions exist: ELECTRICAL SHOCK HAZARD • inverter power button is ON Turning the Inverter mode setting to OFF and/or turning the Inverter Power button off does not disconnect DC battery power from the Freedom HFS.
  • Page 34 Freedom HFS IC Owners Guide.book Page 20 Friday, September 11, 2015 2:54 PM Operating in Inverter Mode Status LED During Inverter Operation Table 2 Status LED during Inverter Operation The following summarizes the behavior of the Status LED during Status Display Inverter operation.
  • Page 35: Checking Output Power

    Freedom HFS IC Owners Guide.book Page 21 Friday, September 11, 2015 2:54 PM Operating in Inverter Mode Checking Battery Status Turning the Audible Alarm ON or OFF During inverter operation, you can check the battery status by The Freedom HFS’s audible alarm can be turned ON or OFF. See pressing the Select button until the Battery Voltage LED (or Battery “To adjust the alarm setting:”...
  • Page 36: Operating During Transition Between Shore Power And Inverter Mode

    Freedom HFS IC Owners Guide.book Page 22 Friday, September 11, 2015 2:54 PM Operating During Transition Between Shore Power and Inverter Mode Transitioning from Shore Power to Inverter The Freedom HFS’s advanced power management is capable of transitioning power from an AC source to DC source within a Mode fraction of a second and vice-versa.
  • Page 37: Operating Limits

    Freedom HFS IC Owners Guide.book Page 23 Friday, September 11, 2015 2:54 PM Operating During Transition Between Shore Power and Inverter Mode Operating Limits Power Output Input Voltage The Freedom HFS can deliver up to 1000 watts or 2000 watts of The allowable Freedom HFS input battery voltage ranges are shown continuous utility grade sine wave AC power.
  • Page 38: High Surge Loads

    Freedom HFS IC Owners Guide.book Page 24 Friday, September 11, 2015 2:54 PM Operating During Transition Between Shore Power and Inverter Mode Overload Conditions Over-temperature Conditions There are two kinds of overload conditions: During inverter operation, when the Freedom HFS’s internal temperature starts to approach its preset shutdown limit, the alarm •...
  • Page 39: Battery Charging

    Freedom HFS IC Owners Guide.book Page 25 Friday, September 11, 2015 2:54 PM Battery Charging Battery charging is possible only when shore power is present and the Freedom HFS unit is connected to a battery (or battery bank). NOTE: Voltage If an external DC load is The frequency of battery charging is determined by how much Bulk...
  • Page 40 Freedom HFS IC Owners Guide.book Page 26 Friday, September 11, 2015 2:54 PM Battery Charging Table 3 illustrates the battery charging status as shown on the Status Table 4 illustrates the battery charging voltage and current settings LED and display screen. for all the models.
  • Page 41: Routine Maintenance

    Freedom HFS IC Owners Guide.book Page 27 Friday, September 11, 2015 2:54 PM Battery Charging Routine Maintenance Freedom HFS Unit Minimal maintenance is required to keep your Freedom HFS operating properly. Periodically you should: • Clean the exterior of the unit with a damp cloth to prevent the accumulation of dust and dirt.
  • Page 42: Invert Power Derating Vs. Ambient Temperature

    Freedom HFS IC Owners Guide.book Page 28 Friday, September 11, 2015 2:54 PM Invert Power Derating vs. Ambient Temperature If the unit is in inverter mode and in elevated ambient temperature above 25 °C, you will have to reduce power draw according to the following chart to avoid over-temperature shutdown.
  • Page 43: Troubleshooting

    Freedom HFS IC Owners Guide.book Page 29 Friday, September 11, 2015 2:54 PM Troubleshooting • Recent sequence of events • Any known unusual AC shore power factors such as low voltage, unstable generator output, etc. ELECTRICAL SHOCK AND ENERGY HAZARD •...
  • Page 44: Warning Messages

    Freedom HFS IC Owners Guide.book Page 30 Friday, September 11, 2015 2:54 PM Warning Messages Warning messages in the form of audible alarms and error codes The error codes are listed in Table 5 below. The text in the Error that appear on the display panel screen to alert you to an impending Code column appears on the display screen of the display panel.
  • Page 45 Check for external charging sources, such as an over voltage alternator, and disconnect if necessary. • Confirm that the external charging source is not the cause. The error may be caused by the internal battery charger system. Call Xantrex for support. Check the battery bank.  ...
  • Page 46 Freedom HFS IC Owners Guide.book Page 32 Friday, September 11, 2015 2:54 PM Warning Messages For error code : • the display screen and the alarm will turn off after 30 seconds • after a five-minute shutdown delay, the unit will immediately stop inverting For error codes ...
  • Page 47: Troubleshooting Reference

    Freedom HFS IC Owners Guide.book Page 33 Friday, September 11, 2015 2:54 PM Troubleshooting Reference ELECTRICAL SHOCK AND ENERGY HAZARD Do not disassemble the Freedom HFS. It does not contain any user-serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. Failure to follow these instructions can result in death or serious injury.
  • Page 48 Freedom HFS IC Owners Guide.book Page 34 Friday, September 11, 2015 2:54 PM Troubleshooting Reference Table 6 Troubleshooting Reference Problem Possible Cause Solution No output voltage. The status LED is red. AC shore power is not available or out of operating range and the inverter has shut down with the display screen showing one of the following error codes: •...
  • Page 49 Freedom HFS IC Owners Guide.book Page 35 Friday, September 11, 2015 2:54 PM Troubleshooting Reference Table 6 Troubleshooting Reference Problem Possible Cause Solution No output voltage. The Status LED is green GFCI has tripped or supplementary Check load and reset the GFCI or supplementary breaker. or yellow.
  • Page 50 Freedom HFS IC Owners Guide.book Page 36 Friday, September 11, 2015 2:54 PM Troubleshooting Reference Table 6 Troubleshooting Reference Problem Possible Cause Solution No output voltage. The status LED is not The jumper wire on the power module Ensure the jumper wire is installed if the ignition control feature lighting up.
  • Page 51: Inverter Applications

    Freedom HFS IC Owners Guide.book Page 37 Friday, September 11, 2015 2:54 PM Inverter Applications Motor Loads The Freedom HFS performs differently depending on the AC loads connected to it. If you are having problems with any of your loads, read this section.
  • Page 52 Freedom HFS IC Owners Guide.book Page 38 Friday, September 11, 2015 2:54 PM...
  • Page 53: Specifications

    Freedom HFS IC Owners Guide.book Page 39 Friday, September 11, 2015 2:54 PM Specifications NOTE: Specifications are subject to change without prior notice. Physical Specifications Freedom HFS 1055 models Freedom HFS 2055 models L × W × H 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) 19.2”...
  • Page 54 Freedom HFS IC Owners Guide.book Page 40 Friday, September 11, 2015 2:54 PM Specifications NOTE: These are inverter specifications. DC Input Freedom HFS 1055 models Freedom HFS 2055 models Operating voltage range for all models 10.5–16.5 VDC (low limit) 10.5–16.5 VDC (low limit) 11.8–16.5 VDC (mid limit) 11.8–16.5 VDC (mid limit) 12.1–16.5 VDC (high limit)
  • Page 55 Freedom HFS IC Owners Guide.book Page 41 Friday, September 11, 2015 2:54 PM Specifications NOTE: These are charger specifications. AC Input All models Operating voltage range 90–140 VAC Safe non-operating voltage range up to 240 VAC Full load maximum current 16 Arms Nominal frequency 60 Hz...
  • Page 56 Freedom HFS IC Owners Guide.book Page 42 Friday, September 11, 2015 2:54 PM...
  • Page 57 Freedom HFS IC Owners Guide.book Page i Friday, September 11, 2015 2:54 PM...
  • Page 58 Freedom HFS IC Owners Guide.book Page ii Friday, September 11, 2015 2:54 PM Schneider Electric Solar Inverters USA Inc. +1 800 670 0707 +1 408 987 6030 www.xantrex.com 975-0727-01-01 Printed in China...

This manual is also suitable for:

807-2055-02807-1055-02807-2055807-2055-01

Table of Contents