4.2.10 HP/PE Sensor removal

1.
Remove the Housing from the printer. (Refer to Section 4.2.1 "Housing
Removal")
2.
Remove the LD roller from the LD roller shaft holder. (Refer to Section 4.2.9 "LD
Roller removal")
3.
Remove HP or PE detection lever from the LD roller shaft holder and disconnect
the cable from the sensor connector
HP detection lever
Fixing nooks
PE sensor
Figure 4-36. Removing the HP or PE detection lever
4.
Release each two hooks of HP and PE sensors securing them from the LD roller,
then remove the sensors.
Disassembly and Assembly
Tor
HP sensor
Fixing nooks
PE detection lever
Disassembly
Make sure that the Torsion spring 0.22 is hung to the following
suitable position
Figure 4-37. Torsion spring 0.22 for PE detection lever
HP detection lever
Figure 4-38. Torsion spring 0.22 for HP detection lever
Revision A
Torsion spring 0.22
PE detection lever
Torsion spring 0.22