Overview Of Operation - Canon iR7086 Series Service Manual

Hide thumbs Also See for iR7086 Series:
Table of Contents

Advertisement

Chapter 5

5.3.4.3 Overview of Operation

iR7105 / iR7095
1. In a Wait State
No. 1 mirror base: at shading position
scanning lamp: off
original sensor
2. ADF Being Opened
No.1 mirror base: moves to a specific point of original detection
scanning lamp: off
original sensor: off
3. ADF Being Closed
No. 1 mirror base: at point of original detection
scanning lamp: off -> on
original sensor: original detection operation
- When the ADF is at 25 deg or lower, the external light within the width of any original is kept out of external light, thus causing the machine to assume the
absence of an original at points of external light detection (external light search operation).
The ADF open/closed sensor (main body) identifies the state as being "closed," and the machine starts original size detection.
Here, B5, B4, A4, and A3 are eliminated from the list of possible sizes.
- When the external light search is over, the machine turns on the xenon lamp for the main scanning lamp, and checks the CCD (4 points) for external light. For
sub scanning direction, the machine starts to operate the original sensor.
4. ADF Fully Closed (8 deg or less)
No. 1 mirror base: at point of original detection
scanning lamp: on
original sensor: original detection operation
The machine looks for a change in the output level of individual sensors for a period of 2 sec after the ADF open/closed sensor (ADF) has identified the current
state as being "closed." The absence of a change in the level causes the machine to assume the presence of an original at the point in question.
The machine uses the combination of changes in the levels of 5 points to identify the size of the original in question.
5. In a Wait State (for a press on the Start key)
No.1 mirror base: at point of original detection
5-14
3
present
4
absent
Result
Scanning lamp
Original sensor
Point of detection 1
ADF
Point of detection 2
Point of detection 3
Reader unit
Point of detection 4
CCD point of original detection
F-5-26
(external
light)
F-5-27
(external
light)
F-5-28
25
F-5-29
8
F-5-30
present
absent
B5
Platen
glass
0010-7900