2) Arrange the mirror positioning tool so that it is ready for use in the ma-
chine (by changing the pin position; FRONT).
[A]
[B]
3) Fit the pins of the mirror positioning tool (front [2]; rear [3]) into the ap-
propriate holes of the No. 1/No. 2 mirror base).
[B]
[A]
[B]
F-5-169
[C]
[B]
[A]
F-5-170
[1]
F-5-171
4) Secure the end of the cable that has temporarily been fixed in place on the
hook of the reader unit frame.
5) Fully tighten the screws on the cable fixing plate both at the front and the
rear.
6) Detach the mirror positioning tool (FRONT, REAR).
7) Put the detached parts back on by reversing the foregoing steps.